GPS route file: RTMONT.mps
In equipment building/room with large heating unit near
monastery.
Will need to call ahead to make sure caretaker will
be there for access.
No special servicing requirements.
* Need GPS serial number.
* Batteries need to be replaced with an AC power supply.
2004:027 – Serviced
station, retrieving 1 data flash card. Obtained GPS
serial number and replaced 2 batteries with a power
supply and a single battery. Note: electricity was initially
turned off, but we found a red lock box just outside
the door with a breaker switch. Once turned to the “ON”
position, the room had electricity. When leaving the
station site, we bumped into the Michele who asked (again)
for a hard copy of a letter of permission from the boss
of Montella for participation in the experiment. After
discussion, we decided that approaching the boss may
stir up more trouble, so no action was taken.