;for hudson horizontal test - beams 1,2 disabled.
; WH with Lowered ADCP option
; load factory defaults
CR1
; CF - flow control
; auto ensemble cycling, 
; auto ping,
; binary data out
; disable serial out
; enable data recorder
CF11101
; EA EB -heading alignment and bias
EA00000
EB00000
; ED - xducer depth
ED00000
; ES - salinity for sound speed
ES10
; EX - coord transformation
; use beam coordinates
EX00000
;
; EZ - sensor source
; manual values for all
EZ0000000
;
; TE - time per ensemble
;  3 minutes
TE00:03:00.00
;
; TP - min time between pings
; set by WinSC or Plan
; See WP for pings per ensemble
TP00:10.00

; LD - data out
; vel, corr, echo
LD111000000

; LF - blanking
; default value
LF0176

; LN - number of cells
LN015

; LP - pings per ensemble
; 
LP00018

; LS - cell size, cm
LS1000

; LV - radial ambiguity velocity, cm/s
; default value
LV170

; additional cmds not provided by Plan or WinSC
;
; WE - error velocity threshold
; set to max for this test
WE5000
; LJ -  receiver gain
; default value 1  (hi)
; set to lo (0) for Hudson
LJ0
CK
CS
;Deployment hours = 24.00
;Temperature      = 5.00
;Frequency        = 307200