PTCN-IU , LH1-10


Noise Levels at Different Periods

The table below gives the decibel 10% noise level (in db) for each month in several period bands. The 10% noise level is defined as the signal level not exceeded 10% of the time, based on hourly measurements. Each entry in the table is color coded with reference to the New Low Noise Model (NLNM, Peterson, 1993):
navy, -6 db < value-NLNM < -3 db
blue, -3 db < value-NLNM < 3 db
aqua, 3 db < value-NLNM < 6 db
lime, 6 db < value-NLNM < 9 db
yellow, 9 db < value-NLNM < 12 db
orange, 12 db < value-NLNM < 15 db
red, 15 db < value-NLNM < 20 db
fuchsia, 20 db < value-NLNM < 25 db
silver, value-NLNM < -6 db, value-NLNM > 25 db

Black indicates that there was an insufficient number of hourly measurements to calculate a noise level.


Noise levels (PSD) in decibels
Month Chan. Qual. # obs. 518s 439s 373s 316s 268s 228s 193s 164s 139s 118s 100s 85s 72s 61s 52s 44s 37s 32s 27s 23s 19s 16s 14s 12s 10s
202606 LH1-10 AR 626 -129 -130 -128 -126 -123 -122 -122 -126 -127 -128 -133 -137 -139 -140 -143 -144 -144 -145 -144 -141 -134 -128 -125 -125 -123
202605 LH1-10 AR 411 -130 -131 -130 -129 -126 -125 -125 -129 -130 -131 -135 -138 -139 -141 -142 -143 -143 -144 -144 -141 -137 -130 -124 -126 -125
202604 LH1-10 AR 718 -133 -134 -133 -129 -126 -125 -126 -129 -131 -132 -137 -140 -141 -142 -143 -144 -143 -144 -144 -143 -140 -135 -130 -127 -128
202603 LH1-10 AR 737 -132 -133 -133 -129 -125 -126 -126 -129 -131 -132 -137 -140 -141 -142 -144 -145 -145 -146 -145 -143 -141 -137 -131 -129 -128
202602 LH1-10 AR 655 -134 -135 -135 -131 -128 -128 -129 -132 -133 -134 -139 -143 -143 -144 -146 -147 -147 -148 -148 -147 -142 -136 -134 -131 -131
202601 LH1-10 AR 216 -133 -135 -135 -131 -128 -128 -129 -132 -134 -134 -138 -141 -142 -142 -144 -145 -145 -145 -145 -144 -142 -136 -133 -131 -131