Product: IESX

Version: 10.1

Application: DataManager

Search Type: BugList


Topic:
Data Loader: Survey origin cannot be reviewed after providing coordinates when creating a 3D survey.

Description:
SYMPTOM: Data Loader: After providing the coordinates and creating a 3D survey, users can't review survey origin to verify accuracy.


Solution:
WORKAROUND: None available. RESOLUTION: In GeoFrame 3.0, after creating the 3D survey, the three points' coordinates will appear if the survey is selected. Also, the first trace popup, which is presented before loading the first 3D trace, will contain the CDP, in-line origin to verify coordinates.

Last Modified on: 24-NOV-98