Product: IESX

Version: GeoFrame 3.0

Application: Seis3DV/2DV

Search Type: BugList


Topic:
Trace decimation incorrect on seismic display when start trace is an even number.

Description:
SYMPTOM: When the start trace is defined as an even number through Display > Seismic line and Trace decimation is set equal to 2 through Define > Scale, the display skips to the next odd number. Example: Start trace = 10, Trace decimation = 2 The seismic display begins at trace 11.


Solution:
WORKAROUND: None available. RESOLUTION: Fixed in GeoFrame 3.5.

Last Modified on: 04-NOV-98