Product: IESX
Version: GeoFrame 3.0
Application: Seis3DV/2DV
Search Type: BugList
Topic:
Trace decimation incorrect on seismic display when start trace is an even number.
Description:
SYMPTOM: When the start trace is defined as an even number through Display >
Seismic line and Trace decimation is set equal to 2 through Define >
Scale, the display skips to the next odd number.
Example: Start trace = 10, Trace decimation = 2
The seismic display begins at trace 11.
Solution:
WORKAROUND: None available.
RESOLUTION: Fixed in GeoFrame 3.5.
Last Modified on: 04-NOV-98