Topic:
SP curve not upgrading correctly or deleted.
Description:
When upgrading from IESX 10x to GeoFrame 3.5 or 3.6, the SP curve values are either incorrect or not upgraded at all. Errors recorded in upgrade log: Loading well log record #10 of 50... **** Unable to create Welllog nam: "sp" ==> Skipped. **** (skipped log was on well "ambar_01") **** Error code = 104022060 **** Failed to convert to RP66 units: 0.22046229E-05 m2.lb/As3. **** Error stack: **** Failed to convert to RP66 units: 0.22046229E-05 m2.lb/As3. **** Error adding the GF record **** ADD_RECORD_FAILURE **** Curve representation could not be added to database **** Could not create a log.
Solution:
Update SP curves in IESX 10x to code SP and no unit. (Select the blank in the unit list in DataManager > Wells > Log header/units). To generate a list of log curves in your IESX 10x project, run IESX_UTIL/option 74. Well report. Fixed in GeoFrame 3.7.
Last Modified on: 29-NOV-99