Product: IESX
Version: GeoFrame 3.6
Application: Project Upgrade
Search Type: BugList
Topic:
SP curve not upgrading correctly or deleted.
Description:
When upgrading from IESX 10x to GeoFrame 3.5 or 3.6, the SP curve values are
either incorrect or not upgraded at all.
Errors recorded in upgrade log:
Loading well log record #10 of 50...
**** Unable to create Welllog nam: "sp" ==> Skipped.
**** (skipped log was on well "ambar_01")
**** Error code = 104022060
**** Failed to convert to RP66 units: 0.22046229E-05 m2.lb/As3.
**** Error stack:
**** Failed to convert to RP66 units: 0.22046229E-05 m2.lb/As3.
**** Error adding the GF record
**** ADD_RECORD_FAILURE
**** Curve representation could not be added to database
**** Could not create a log.
Solution:
Update SP curves in IESX 10x to code SP and no unit. (Select the blank in the
unit list in DataManager > Wells > Log header/units). To generate a list of
log curves in your IESX 10x project, run IESX_UTIL/option 74. Well report.
Fixed in GeoFrame 3.7.
Last Modified on: 29-NOV-99