Topic:
"Please hit return to continue" using IESX_Utilities 72 and 73.
Description:
Open IESX_UTILITIES>run Utility 1 and it connects to the project>choose Utility 72 or 73 and you are returned to the list with "please hit return to continue". Other utilities will run ok, but not 72 and 73.
Solution:
These Utilities will not run if the project description is too long (62 character limit). To edit the project description in GeoFrame: 1. Project Manager>edit. 2. In the the "Edit Project Parameters" window, either delete the description, or edit it to less than 62 characters. 3. Utilities 72 and 73 should run normally now.
Last Modified on: 28-DEC-00