Product: IESX
Version: GeoFrame 3.8
Application: Computation Manager
Search Type: BugList
Topic:
Processing stops before the end depth of seismic.
Description:
Has seismic in depth with a non-zero postive start time.
The seismic range is 1500 m to 4000 m.
SeisAn (filter, agc) stopped working at 2500 m.
Solution:
Computation Manager is not getting the end depth correctly. It is not taking
into consideration the start depth. In this case it sees a trace length of 2500
and therfore stops processing at 2500. This is only a problem for depth data
that has a positive dfs (depth of first sample). Time data is ok.
This is a problem with filter and agc.
Work Around:
In the Selected Operations box do:
Bulk Shift
Filter
Bulk shift
Use the first bulk shift to start it at zero depth.
Select the operations needed, filter, agc, ...
Use the second bulk shift to move it back to the original start depth.
Fixed in GeoFrame 3.8.1
Last Modified on: 16-FEB-01