Product: IESX
Version: 10.2
Application: Synthetics
Search Type: Error
Topic:
Application seismic dialog failed; db token (0,0,0) is incompatible with fid 101008009
Description:
Database object token - field id mismatch
db token (0,0,0) is incompatible with fid 101008009
Solution:
The error message is caused when Synthetics tries to post the reference seismic
on the panel. The nearest seismic line to the default well either has no
navigation information (2D) or has been unshared, but not deleted (3D).
Also check the class priority list and make sure Synthetics is not trying to
post data from an empty seismic class. Delete all empty classes using Data
Manager > Utilities > Delete.
Last Modified on: 12-OCT-98