Product: IESX
Version: 10.2
Application: Seis3DV/2DV
Search Type: Error
Topic:
Error displaying picture; Seismic display creation failed; db token failed.
Description:
Seismic display creation failed
Error displaying picture
Error rendering seismic facet
Error initializing va routines
Error initializing va mode rendering
Mode rendering sessions
Clip level specified is too large
The seismic window opens fine, but when selecting a line the user gets a
'db token failed' error.
db token failed
Solution:
If displayed in variable area (VA) mode, the line may have clip values
that are too large. To change the clip values, go into Define -> Display
Specs. In the bottom right part of the menu, the 'wiggle trace' box,
adjust the negative and positive clip values to less than 63.00 (for example,
adjust them to 5 each). After doing this, the seismic window opens.
Last Modified on: 07-AUG-98