Product: IESX

Version: 10.1

Application: Computation Manager

Search Type: Error


Topic:
Attribute volume callback failed

Description:


Solution:
First, check to see that you have enough disk space on your DSL(s). This can be done in IESX Session Manager, Project> Update>, select your project, and it will show the DSL's associated with the project. If you need more space, see the entry under: Product: IESX Application: Project Management Topic: How to add a new DSL to a project. If the error still occurs once you are sure you have enough disk space, check the CDP and SP values. In SeisXDV, display CDP and SP numbers along the top of your seiemic. Visually inspect the SP and CDP numbers in the seismic you are trying to run through Computation Manager. If you note any strange behavior, go to Datamanager> Renumber 2D, select the survey and line you are working on, and examine the renumber tables, and fix them if necessary.

Last Modified on: 24-AUG-98