Product: IESX
Version: 10.1
Application: Seis3DV/2DV
Search Type: Error
Topic:
Seismic display creation failed; Error breaking interpretation; Can't close file
Description:
Additional information:
Error breaking interpretation
db_e_ntrp_flt_path_read
Can't close file
File was not open
Error accessing bat file
db_e_file_not_open
Error opening file
Error in primitive io operations
Unknown status s% = %d
Solution:
Run IESX_Utilities option #22 (Rebuild Interpretation).
NOTE: Make sure you have a recent full backup of the project before running
this option.
1. Select iesx_util.csh from the Application Selection menu and click the
'Start' button;
2. Enter #1 to initialize data area
a. Enter project name and password;
b. Enter #1 for Exploration area.
3. Enter #22 to rebuild interpretation
Enter a temporary directory with enough space to run this utility.
NOTE: The approximate space required is the total space currently used
by the *.fpb, *.idx, and *.dat files in the directory containing
the IESX *.idx files to be rebuilt.
4. Upon successful completion, enter #2 to terminate access to the data area.
5. Enter #99 to exit IESX_Utilities
Last Modified on: 11-AUG-98