Product: IESX
Version: 10.2
Application: IES Data Management
Search Type: Error
Topic:
Error loading new wells: "error getting old path, s.v.=20547, 5043h."
Description:
Loading a large ASCII file of path and top data for over 640 wells into
an IESX project converted from IES which previously had no wells. While
attempting to load the data, the first well loads, then it errors out with the
message above.
Solution:
The 5043h error is a maploc error. Rebuild the maploc files:
1.) Session Manager > Application > IES DataManagement*
2.) ADD data to project
3.) Add Data in IES format
4.) Create a NEW PROJECT INVENTORY (set the 'Restore MAPLOC files' to
'REBUILD')
5.) EXIT, EXIT to run the process
After rebuilding the maploc files, the error changed to a status value of 5059
with the same text. In the actual file containing the data, some of the wells
contained only header information and no end of data flag (EOD) immediately
after the header flag. This caused the next well header information to be
read as data information.
The 5059 error, getting old path, can also be an ldb problem. Rebuild the maploc
and the LDB files (IES Data Management as described above, #4 set the 'Restore
LDB files' to 'REBUILD'), and fix the data file. Then reload.
* IES Data Management is not a Motif-based application. Therefore you will use
arrow keys and the Return key on your keyboard rather than the mouse.
. To move across a screen and toggle through options, use the left and right
arrow keys
. To activate your selection(s) and return to the preceding screen, move the
cursor to EXIT and press Return on your keyboard.
. To return to the preceding screen without activating your selection(s), move
the cursor to QUIT and press Return on your keyboard.
Last Modified on: 18-NOV-98