Product: IESX
Version: GeoFrame 3.1
Application: Seis3DV/2DV
Search Type: Error
Topic:
IESX - unexpected SIGSEGV received.
Description:
This error occurs when a GeoFrame 3.0 project is being opened with the
GeoFrame 3.1 software. The saved sessions from GeoFrame 3.0 project are not
properly recognized with GeoFrame 3.1 due to added functionality. For example,
when opening IESX, GeoFrame 3.1 will try to use the saved sessions, and if the
saved sessions are from GeoFrame 3.0 IESX will come up and then disappear with
some error messages.
Solution:
Eliminate the saved sessions from the GeoFrame 3.0 project. To do this, open
the Seismic Catalog. Click MB1 once on the terminal icon next to 'IESX'. Click
once on any listed sessions under IESX and then click MB1 on the red X icon in
the upper right side of the window. Do this for all of the saved sessions. Now
double-click on IESX and it will start without a saved session.
Last Modified on: 24-MAR-99