Product: IESX

Version: 10.2

Application: Seis3DV/2DV

Search Type: Error


Topic:
Error %s=%d when attempting to open Seis3DV/2DV

Description:
User was in project when server went down. After re-entering project the error appears: error %s=%d when attempting to open Seis3DV/2DV.


Solution:
Dismiss the error and continue working. If the error appears again with the addition of a 'gkio' message, then delete the user's saved sessions as follows: 1) Back out of the IESX project 2) On a UNIX level, 'cd' to the '/home/gqs/iesx_config/user' directory (where the 'user' part of the path is actually the user's login name). 3) In the '/home/gqs/iesx_config/user' directory, make a copy of the eight files elsewhere. Then, delete the eight files in the directory. 4) Reenter the IESX project and the eight files will be rebuilt. note: Deleting the user's saved sessions files deletes that user's saved sessions for all projects.

Last Modified on: 11-AUG-98