Product: IESX
Version: GeoFrame 3.0
Application: Project Upgrade
Search Type: Error
Topic:
Project Upgrade fails. Error 124000054 File open failure.
Description:
Project Upgrade fails; the $IESX_CONFIG directory is not correctly defined in
the GeoFrame 3.X environment.
The following error has occured: 124000054
CAN_RENAME_PATHS completed unsuccessfully.
Project Upgrade failed.
Error code = 124000054
Error stack:
File doesn't exist : "IESX_CONFIG:da.info.key'
File open failure.
Solution:
1) IESX and GeoFrame 3.0 MUST use the same $IESX_CONFIG for project upgrade to
successfully complete.
To check this: in an IESX xterm type: echo $IESX_CONFIG
in an GeoFrame xterm type: echo $IESX_CONFIG
If they are different edit the following GeoFrame file:
$GF_HOME/iesx/iesx_setup_site.csh
Look for the following line and edit the config path.
setenv $IESX_CONFIG /home/gqs/iesx_config/
(or the complete pathname recieved from $IESX_CONFIG in IESX xterm)
2) Restart the Upgrade IESX project application.
Last Modified on: 20-AUG-98