Topic:
Nothing happens when trying to open SeisDV
Description:
After selecting any of the SeisDV options from the Application > Interpretation menu in the IESX Session Manager, nothing happens. The computer appears to be "thinking" but the window never opens. Basemap and the DataManager open fine (and presumably all other options).
Solution:
The seismic was being shared into the project and the survey names had been renamed in the project being shared from. During renaming the surveys, the shared references were broken. Unsharing and resharing the seismic will allow you to view the seismic. However, the interpretation will not move to the new surveys. In an IESX project, the interpretation data is hung with the survey. Therefore, you will have to either turn on crossposting when posting the interpretation, or export the interpretation and load it back into the project with the newly named survey. Ultimately, it may be better to just set the survey names back to what they were originally named.
Last Modified on: 01-OCT-98