Product: IESX
Version: 10.2
Application: DataManager
Search Type: Error
Topic:
Error creating seismic volume; Status = 104001173; Invalid object token.
Description:
DataManager > Seismic > Load Seismic.
Receive the following error attempting to load seismic:
'Error creating seismic volume.
Status = 104001173
Invalid object token.'
The progress report window indicated no errors in the loading definition.
Solution:
The data loader has become corrupted. Any new loading definition
created in the original project will error out with the above error.
First, exit IESX and re-enter with the project's saved session and try loading
again. Second, if it still fails, exit IESX and re-enter project with a new
session. If both of these routines fail, then do the third option below:
Third, create the same loading definition in a "dummy" project and import into
the original project.
1.) Create "dummy" project.
2.) Create/save a loading definition in this project in
DataManager > Load Seismic. Exit "dummy" project.
3.) Enter the original project and import the newly created
loading definition through DataManager > Utilities > Import.
Select the "dummy" project from the list, toggle item type
to 'Seismic Application files' and import the loading
definition (file_name.ldfx).
Last Modified on: 15-DEC-98