Product: IESX

Version: 10.2

Application: CPS-3 Link

Search Type: Error


Topic:
Error: cps dm_gv_handle_query (failed)

Description:
cps dm_gv_input_cv (failed) cps dm_com_well_top (failed) invalid well object The error occurred selecting 'Well Tops...' by 'Well Sets' and the set contained markers in MD (measured depth).


Solution:
The depth index for the marker depth values must be TVD (true vertical depth) to be selectable in CPS-3 Link and convert sucessfully. WORKAROUND: Change markers in IESX from MD to TVD. How to change markers to tvd: 1.) Data Manager > Wells > Markers > Select the wells, formations, sources and click on Convert markers. 2.) Select the 'To TVD button' and 'Overwrite existing values'. 3.) Operate. To recover the original MD marker values repeat the same steps but turn the 'To MD' toggle on instead of the 'To TVD' toggle. Note: When you convert the markers, you are converting them based on the current well path and the current DVT associated with the well. If any changes are made to well path or DVT, the original MD marker values cannot be recovered.

Last Modified on: 23-NOV-98