Product: IESX
Version: 10.2
Application: Project Converter
Search Type: Error
Topic:
ERROR_IDA_LINE_GET Status = 24064, 00005e00H
Description:
The following error occurs when attempting to convert 3D interpretation from
IES to IESX when some of the interpretation is not associated with any
seismic trace data (i.e. a reconstruction cut was deleted and its associated
interpretation was not).
Solution:
To delete the excess interpretation run fixdb on the project:
1.) From the Session Manager select:
Application > IES Data Management > Execute Management Utilities >
Execute OS Commands in a subprocess
2.) From the UNIX prompt type:
> $TOOLS/fixdb
3.) Run through each of the 5 options in order.
Option 3, Check profile data, contains an additional 5 options.
Run through each in order.
For projects with extremely large amounts of seismic data, don't run
option 4, Check seismic data, unless a problem with the seismic data
has been detected.
Last Modified on: 23-SEP-98