Product: IESX
Version: 10.0
Application: Project Converter
Search Type: Error
Topic:
DB_E_NTRP_ATTR_WRITE Status = 104014019, 20c3H
Description:
Interpretation had been successfully transfering. Received error when the
interpretation DSL reached 100% capacity.
DB_E_INTRP_ATTR_WRITE
Status Value = 104014019, 20c3H
Solution:
1.) Increase the interpretation DSL (disk storage location) space in the
IESX project.
Session Manager > Project > Update > Interpretation DSLs
Add an additional interpretation DSL and set the spanning DSL criteria.
2.) Delete partially converted interpretation from the IESX project using
iesx_util.
Exit from the IESX project and select iesx_util.csh from the IESX
Application Selection menu. Start.
-Select option 1, Initialize access to a data area.
-Enter name for data area: 'project name'
-Enter password for data area: 'project password'
-Select Data Area Type => Exploration
-Select option 21, Delete all interpretation.
-Select option 2, Terminate access to a data area.
-Select option 99, Exit iesx_util
3.) Restart the Project Converter application and convert all interpretation
from IES to IESX.
Last Modified on: 17-SEP-98