Topic:
Bus Error converting 2D seismic.
Description:
Solution:
A common occurrence of this error is when 'Auto generate' is used for the output seismic class in the IESX project. There is a limit of 64 classes per project. Auto generate creates a new class of data for EVERY 2D seismic line transfered causing this limit to be exceeded. Suggested workaround: 1.) Delete the 2D survey in the IESX project (which will delete all auto generated classes) and re-convert using the 'Create new class' option. DataManager > Utilities > Delete Select item type of 2D survey to delete. OR 2.) Use DataManager > Change Class in the IESX project to move the seismic data to a common class name. Then delete the redundant classes using Data Manager > Utilities > Delete Select item type of 'Unused seismic classes' to delete.
Last Modified on: 23-SEP-98