Product: IESX
Version: GeoFrame 3.1
Application: Seis3DV/2DV
Search Type: Error
Topic:
DB token (0,0,0 ) is not a member of inventory 1792
Description:
After selecting a 2d line from Display > Seismic line, received following error:
Seismic Display creation failed
Additional Information
Content Display type and Path type Mismatch
Cannot update an unmaned view path
Error creating a new path: ( in path_util )
Status: DB_E_PATH_NOT_COPIED
STATUS: DB_E_PATH_RECORD_NOT_FND
Database object token - inventory mismatch
DB token (0,0,0 ) is not a member of inventory 1792
Solution:
1.) Check the navigation for accuracy in DataManager > Map > 2d Edit Locations.
Check the translation tables in DataManager > Seismic > Renumber 2d for
2.) Delete the db_physpath file using option 44 in iesx_util.csh. Deleting this
"file" will remove all saved path information from the project: rectangular paths, polygonal paths, etc. See the FAQ below on how to do this.
Project: IESX
Version: GeoFrame 3.1
Application: IESX Util
Search Type: FAQ
Synopsis: What does Option #44: Delete db_phys_path file do?
3.) If this doesn't work, you are left with the option of creating a clone and
sharing over seismic and interp or restoring from backup. See the How To
creating a clone below:
Project: IESX
Version: 10.2
Application: Project Management
Search Type: How To
Synopsis: How to create a clone of an IESX 10x project.
Last Modified on: 16-OCT-98