Topic:
Error posting borehole: mt_e_object_well_rebuild
Description:
After adding a deviation survey, trying to post the borehole gives error: mt_e_object_well_rebuild mt_e_mem_well_rebuild mt_e_cache_well_data_load_fail mt_e_mem_well_data_load_fail mt_e_mem_well_data_load_items invalid object token object record not found error reading GF record mt_e_inv_tkn Borehole will not post
Solution:
This error is caused by an aliasing problem with the units. In the deviation survey, open the General attribute editor and check the units. If the units are set to FT, instead of ft, the borehole will not post. Change the units to ft and the borehole will post. To prevent the problem from occurring again, go into Project Manager -> Edit -> Set Units -> Inspect, and set the units to ft there as well. For the above error, the user had StandardDepthUnits set to FT.If the borehole still will not post with the units changed to ft,delete and reload the borehole.
Last Modified on: 16-MAR-99