Product: IESX

Version: 10.1

Application: Seis3DV/2DV

Search Type: Error


Topic:
Invalid well token or 7x project locked

Description:
invalid well token or 7x project locked additional information: database object tokens field id mismatch DB token is incompatible with FID 1010022013 Error displaying wells on seismic.


Solution:
1.) First, delete the well sets and create new set. If still error, proceed to step 2. 2.) Run IES rebuild and IESX_UTIL/options 81 and 83: Rebuild inventory via IES Data Management: a.) Session Manager > Application > IES Data Management* b.) ADD data to project c.) Add Data in IES format d.) Create a NEW PROJECT INVENTORY 1 - Rebuild inventory: YES 2 - Confirm recovery: NO 3 - Disposition of old inventory RENAME 4 - Restore LDB files REBUILD 5 - Restore MAPLOC files REBUILD e.) Then EXIT and the process will run. When the process is finished, continue to EXIT until you are out of IES Data Management. * IES Data Management is not a Motif-based application. Therefore you will use arrow keys and the Return key on your keyboard rather than the mouse. . To move across a screen and toggle through options, use the left and right arrow keys . To activate your selection(s) and return to the preceding screen, move the cursor to EXIT and press Return on your keyboard. . To return to the preceding screen without activating your selection(s), move the cursor to QUIT and press Return on your keyboard. NOTE: Look in the rebuild.log in the project directory for error pertaining to wells. If you find a bad well, try to delete it in DataManager > Wells. Running IESX_UTIL: Run option 83 first to list mismatch or errors between IES and IESX well names. Then run option 81 to resync wells. Run option 83 again to see if that fixed the discrepencies. If the names still mismatch, try to delete the well in DataManager > Wells. If you still receive the error, proceed to step three. NOTE: Before proceeding with this step, please make sure you have a current backup of this project. 3.) Run IESX_UTIL, option 82 to rebuild the IESX well database. But first, export markers back to IES in DataManager > Markers. After option 82 has run, then re-import the markers. NOTE: If you were having trouble deleting wells before option 82 was run, you might be able to delete them now. If you are still receiving the error, please contact GeoQuest Customer Support for further assistance.

Last Modified on: 07-JAN-00