Product: IESX
Version: GeoFrame 3.5
Application: Seis3DV/2DV
Search Type: Error
Topic:
Error no coordinate conversion performed, DB_E_MAP_LCS_TO_WORLD_FAILED
Description:
Posting boreholes on 2d line and get the following error message:
Borehole information rendering failed
error no coordinate conversion performed
Status: DB_E_MAP_LCS_TO_WORLD_FAILED
DB_E_MAP_LINEAR_LCS_FAILED
DB_E_MAP_LCS_OUT_OF_RANGE
Solution:
This error message indicates that there is a problem with the 2D navigation
data. Use the following suggestions to identify possible navigation problems.
Remember to check for navigation points that extend beyond the trace data of a
line and for navigation points that share the same xy location.
1. Check/fix line locations in IESX DataManager > Edit 2D locations
2. Check/fix line numbering in IESX DataManager > Renumber 2D
3. Run IESX Utilities #37 Shotpoint table scanner and #39 Compression of
shotpoint tables.
4. Run IESX Utility #38 Extrapolation of XY coordinates if the navigation does
not extend to the end of the segy data.
5. Delete the 2D navigation and reload.
Last Modified on: 31-JUL-00