Product: IESX
Version: 10.2
Application: Seis3DV/2DV
Search Type: Error
Topic:
MT_E_DISP_ATTR_DATA_POLYLINE_FAILED
Description:
Interpreting on 2D data and getting the following error message upon breaking.
MT_E_DISP_ATTR_DATA_POLYLINE_FAILED
MT_E_DISP_NTRP_ATTR_1_OBJECT_FAILED
MT_E_PROJ_XY_LCS_FAILED
Solution:
Check the 2D navigation. Correct any mismatch between the seismic shotpoint
range and the 2D navigation shotpoint range in IESX > DataManager > Edit 2D
Locations. They should match. Also, check Renumber2D for multiple tables. Please
see the FAQ's on IESX_UTIL options from the Knowledge Base to fix this error:
IESX_UTIL options:
38. Extrapolation of xy coordinates (Extends location data to the beginning
and/or end of a 2D seismic line if the navigation is not present)
39. Compression of shotpoint tables. (compress multilple shotpoint tables)
72. 2D General Data Manager (retie 2d lines after fixes)
Last Modified on: 19-JUL-00