Product: IESX

Version: 10.1

Application: Project Converter

Search Type: FAQ


Topic:
2D shotpoint numbering inconsistent after conversion from IES.

Description:


Solution:
Shotpoint increments in IES are stored to 3 decimal places. i.e. 0.333, 0.666 (11 decimal places for IESX) When tracking across the seismic the SP increment will not be consistant due to rounding errors. 1.) Correct the shot point increment in IESX to 0.33333333333. DataManager > Seismic > Renumber 2D 2.) Retie the navigation in IESX. DataManager > 2D line location - Select any point on the line - Click 'Change' Although an increment of 0.333 will appear in the table an increment of 0.33333333333 will be stored and the tracking will be consistant.