Product: IESX

Version: 10.2

Application: CPS-3 Link

Search Type: FAQ


Topic:
Why are Total Depth (TD) values coming across CPS-3 Link as 0.000?

Description:
Data types transferred from IESX to CPS-3 are: X, Y, total depth (TD) and Well Name data. The TD data values that come across to CPS-3 are 0.000.


Solution:
In IESX, TD values are stored in DataManager > Wells > Wells > Driller TD and cannot be transferred to CPS-3 via the CPS-3 Link. WORKAROUND: You have two options. (1) Save (or read in) TD data as a marker TD (input as TVD, cannot transfer MD) in IESX and use the CPS-3 Link to transfer marker data into CPS-3. (2) Manually edit each TD value from the CPS-3 Model Editor.

Last Modified on: 23-NOV-98