Product: IESX
Version: 10.2
Application: IES Data Management
Search Type: FAQ
Topic:
Reloaded a path in IES Data Management, but do not see the changes in IESX.
Description:
A well path was loaded into the project via IES Data Management. Then the
well path needed to be changed, so reloaded the edited well path into IES Data
Management. However, after reloading the well path, the IESX
Data Manager did not reflect the changes in the well path.
Solution:
In order for the change to show up in IESX Data Manager (Wells/Wells/Deviation
survey) the well path must first be deleted out of IESX DataManager, and then
reloaded via IES Data Management. (Or, just make the change in IESX Data
Manager manually.)
To delete the well path out of IESX DataManager:
1. Session Manager > Application > DataManager > Wells > Wells
2. Select the well from the list in the upper left corner of the menu.
3. Click on the 'Deviation survey' button at the lower right of the menu.
4. In the 'Well deviation' menu, click on the 'Clear' button and confirm the
clear
5. In the 'Well deviation' menu, click on the 'Update' button and then click
on the 'Dismiss' button, and the well path will be cleared out of the database.
Then proceed to reload the well path via IES Data Management.
Last Modified on: 18-NOV-98