Product: IESX

Version: GeoFrame 3.1

Application: IESX Util

Search Type: FAQ


Topic:
What does Option #32: Update seismic volume statistics do?

Description:


Solution:
This option recalculates seismic amplitude statistics. This function reads all seismic trace header information and updates the corresponding seismic volume header statistics information for the selected volume. 1.) Run this function if reloading or nulling out an area of data. 2.) Check the accuracy of the amplitude readout by comparing DataManager > Report > Seismic Report (static) and DataManager > Report > Amplitude Statistics (on the fly). They should be the same. PROCEDURE: 1.) Option #1 - Initialize access to data area. - Enter the project name and password. - Select Exploration as Data Area Type. 2.) Option #32 - Update seismic volume statistics. - Select SEIS Record, enter your Selection. 3.) Option #2 - Terminate access to the data area. 4.) Option #99 - Exit IESX_Utilities.