Topic:
When will I be able to start my plot at a dead trace?
Description:
In the past when you started your plot at a dead trace the entire plot showed up with all dead traces.
Solution:
In GeoFrame 3.0 you have the choice to use PIP plotting. PIP uses scalars for every trace, whereas CGM+ takes the first trace only and uses it as a scalar. PIP plotting is an additional software package offered by the plot rendering vendor e.g. ZEH or SDI.
Last Modified on: 25-NOV-98