In Load wells, what does the WEll ID Priority toggle do?
Description:
Solution:
This toggle is used when loading wells with either duplicate well names or
duplicate uwi's.
In the case of duplicate well names set this toggle to "uwi". By doing this you
are telling IESX that there will be wells with duplicate names but the uwi's
will be different. Lets say that you have 3 wells with the name "testwell", but
all 3 have different uwi's. By setting the toggle to "uwi" it will force IESX
to load those wells with different names. It will load the 3 wells as
testwell_001
testwell_002
testwell_003
Setting the toggle to "well name" will do the same as above, but to the uwi
number.
This way there will be no duplicate well names or uwi's in the database.