Product: IESX

Version: GeoFrame 3.5

Application: Seis3DV/2DV

Search Type: FAQ


Topic:
Class priority is not honored when a composite path is made.

Description:
When a composite path is made from two different classes of data, one part of the seismic display of the composite has null traces and does not honor the set class priority.


Solution:
To get the composite to honor the class priority set in SeisDV, go to Define -> Display Spec... and toggle 'Non-existent data uses' from Null traces to 'Class priority list'. Click OK and the display will now use the class priority list and fill in the null traces with the appropriate class of data.

Last Modified on: 09-MAY-00