Topic:
What is the easiest way to create a Variance Cube from a flattened volume?
Description:
Variance Cube does not recognize flattened volumes as a valid input. What is the easiest workaround?
Solution:
Simply rename the flattened volume in IESX > Data Manager > Change Class. The flattened volume will then be available for selection in the Variance Cube input menu. Once the name of the flattened class is changed, the program no longer recognizes it as a flattened volume. If a flattened volume is still needed, either generate another one or change the name of the flattened class back to its original name.
Last Modified on: 27-JUL-00