Product: IESX
Version: 10.2
Application: DataManager
Search Type: HowTo
Topic:
How to copy mistie data back to the seismic project.
Description:
I shared data from two different surveys contained in the master seismic
project. In the clone, I then moved those lines into a single survey and ran
mistie analysis on the data. How do I copy the mistie data back to the master
seismic project?
Solution:
1.) In the clone project, move the lines back to the original surveys:
DataManager > 2D seismic > 2D surveys
- Select surveys from the '2D surveys' and select the line's to move.
- Select the appropriate 'Move-> or Move<-' and 'Dismiss'.
2.) In the seismic project, share the mistie class of data from the clone
project to the seismic project:
DataManager > Seismic > Share
- Select clone project.
- Select clone 2d survey and mistie class.
- Select 'Share' and 'Dismiss'.
3.) Copy the mistie class in the seismic project to a new class in the clone
project:
DataManager > Seismic > Copy
- Select survey and 2d lines.
- Select Input class.
- Type in output class name.
- Select 'Generate'.
4.) Unshare clone project:
DataManager > Seismic > Share
- Select survey in 'Remove outgoing references'.
- Click 'Unshare'.
Last Modified on: 04-DEC-98