Product: IESX
Version: 10.2
Application: CPS-3 Link
Search Type: HowTo
Topic:
How to import depth markers from IESX to CPS-3.
Description:
Markers in the IESX 10.2 project have both time and depth values. Only time
values come across when the markers are imported to CPS-3 via CPS-3 Link.
Depth values in MD will not show up on the list in CPS-3 Link.
Solution:
The depth index for the marker depth values must be TVD (true vertical depth)
to be selectable in CPS-3 Link and to convert successfully.
WORKAROUND: Change markers in IESX from MD to TVD.
How to change markers to TVD:
1.) DataManager > Wells > Markers > Select the wells, formations, sources and
click on Convert markers.
2.) Select the 'To TVD button' and 'Overwrite existing values'.
3.) Operate.
To recover the original MD marker values repeat the same steps, but turn
the 'To MD' toggle on instead of the 'To TVD' toggle.
Note: When you convert the markers, you are converting them based on the current
well path and the current DVT associated with the well. If any changes are made
to the well path or DVT, then the original MD marker values cannot be recovered.
Last Modified on: 23-NOV-98