Product: IESX
Version: 10.0
Application: Project Upgrade
Search Type: HowTo
Topic:
How to remove shared references in a clone project. Master project previously upgraded.
Description:
All seismic was unshared from the master seismic project in DataManager > Share.
The master project was then upgraded to 10px. The clone project maintains
the shared references and they cannot be removed using DataManager.
Solution:
(A) Patch the 9pX project to break existing shared references.
(1) In an xterm window cd to project home disk location (DSL).
(2) Copy (cp) the project_name.da file to a backup name.
(i.e. project_name.da_save).
(3) From the IESX Application Selection menu select iesx_util.csh. Start.
(4) Select option #3 - Delete data area - from the iesx_util.csh menu.
This option deletes the .da file and removes the project from the
'Select Project' list. This DOES NOT delete any project data other
than the project_name.da file.
(5) In the home DSL, copy the project_name.da_save file back to its
original name.
(6) From the IESX Application Selection menu select iesx_patch.csh.
Enter project name and DSL information.
(7) Reshare any previously shared data.
DataManager > Seismic > Share
(B) Run the upgrade utility.
From the IESX Application Selection menu select upgrade_9px_to_10px.csh.
Last Modified on: 17-SEP-98