Product: IESX

Version: 10.2

Application: DataManager

Search Type: HowTo


Topic:
How to copy a portion of a 3D survey into another project.

Description:
Also, how to merge interpretation on the portioned seismic. There are three ways to do this. 1.) Create a new project using Project_Rename and null out the seismic you do not want to see. 2.) Create a new project and share/copy seismic by cdp/line range. 3.) Segy export cdp/line. range and and reload , export and import interp.


Solution:
Project_Rename method: 1.) Create new project with same projection/units and same number of DSL's as the original project. 2.) Do a UNIX copy of files from master to new project(s), and run "project_rename.csh" under "IESX Application Selection" menu. Make sure you copy Old project/DSL1 to New project/DLS1, etc... 3.) Run Project_rename from the Application Manager and follow intstructions. See "How to" procedure in "Project_Rename". 4.) In the new project, select DataManager > Seismic > Copy, and toggle "Option" button to 'null data' to wipe out the data you don't want to see. 5.) For deletion of interpretation from the nulled area, use DataManager > Interpretation > Delete. Select horizons, faults, and survey(s), but do not select horizon or fault names under "Select items for deletion". Select "Change Area" and input cdp/inline range to delete. To share/copy into new project: 1.) Create new project with same projections/units as original. 2.) DataManager > Seismic > Share, select original project, survey/class and select 'Share'. 3.) DataManager > Seismic > Copy, select original survey/class and type in a new output class. Select 'Change Area' and input cdp/line range you want to copy. Then unshare in DataManager > Seismic > Share. 4.) To merge interpretation over, use DataManager > Interpretation > Merge, select source "original" project, survey, horizons, faults, fault contacts, and traces, select destination survey, and select 'Change Area' to select line/cdp range to copy into to. To segy export and reload: 1.) In original project, DataManager > Seismic > SEGY export, select survey/class, set Output parameters, select 'Change Area' to output cdp/line range to restrict and 'Generate'. 2.) In original project, DataManager > Interpretation > Export, select format, interpretation, survey, select 'Change Area' to restrict output and input filename, 'Export'. 3.) In new project, DataManager > Seismic > Load Seismic and reload using same survey coordinates as before. 4.) In new project, DataManager > Interpretation > Import, select format, input filename, 'View' and 'Load'.

Last Modified on: 04-DEC-98