Product: IESX
Version: 10.2
Application: DataManager
Search Type: HowTo
Topic:
How to load interpretation into a project without seismic.
Description:
Cannot load ascii interpretation (card image 7), as IESX survey does not exist.
Solution:
Either create a dummy survey by loading dummy data for first and last line of
the survey, then load IESX ascii format interpretation.
OR
Geoshare interpretation from IESX to a Local file (RP66). This will also create
the survey definition.
To create Geoshare RP66 file:
1.) Click MB1 on the Geoshare button on the Geonet window.
2.) Select :
From : IESX-10P2
To : Local File
Start Transfer
3.) Enter name for Local file > OK.
4.) IESX Geoshare Data Selector > Select project > Enter Password > Proceed.
5.) Available DDB'S > Seismic Data > Manage.
6.) List > Select Survey name from list > OK.
7.) Select Interpretation > Select Horizons, Attributes, and Faults for export.
Limit Line/CDP range as required.
8.) Enter DDB Name (DDB = Data Definition Block) > Accept.
9.) IESX Geoshare Data Selector > Send.
To Import Geoshare RP66 file to IESX project:
1.) Select :
From : Local File
To : IESX-10P2
Start Transfer
Interpretation can be displayed in Basemap or MapView.
Last Modified on: 04-DEC-98