Hydrology BC ENV 3025
    
    Geochemical measurements
    We will perform measurements on three sets of samples: 
    
      - Hudson River water (collected 2/27)
 
- Pond water from Morningside Park (2/28)
 
- Altschul tap water (2/29)
 
Procedure:
    
      - perform measurements on 
 
        - original water, 
 
- filtered water after gravel and sand filter, 
 
- filtered water after gravel, sand, and charcoal filter
- filter the water and collect fractions in orange vials
- fill a blue vial up to the 10ml mark with original water. We
        will let the water evaporate and look at the residue next week.
        
 
- measure
        - pH with pH strips (put test strip into water until it does
          not change color anymore)
- transfer some water into small glass tube to measure
          turbidity on spectrophotometer
 
- electrical conductivity (put electrode into orange vial,
          rinse in DI water between measurements) 
 
- all original waters should be measured for total coliform (as
        instructed in class); for the Morningside Park pond water we
        will measure total coliform also after each of the two
        filtration stages (see above), for Hudson River water only after
        the second filtration step
 
Please transfer results into Google
        document
      
      Materials
    
      - filter assembly
 
- sharpie
- colialert kit
- conductivity meter
- DI water
- orange and blue vials
 Resources